SECTION 07200
BUILDING INSULATION
SHORT FORM
All insulation as shown on drawings or specified herein
shall be the CORBONDŽ Performance Insulation System as
manufactured by Corbond Corporation of Bozeman, Montana.
CORBONDŽ shall be installed by technicians in accordance
with manufacturer's instructions.
STANDARD FORM
I. General
A.
Related Documents: The general provisions of the contract,
and all codes and standards referenced.
B.
Description of the Work:
1. The extent of CORBONDŽ insulation is shown on the
drawings.
2. The applications of CORBONDŽ include the following:
a. Rigid spray-in-place crawl space perimeter insulation
b. Rigid spray-in-place perimeter wall insulation
c. Rigid spray-in-place ceiling/roof insulation
3. Related work specified elsewhere:
a. Spray-on Thermal Barriers: Division 7 (0718)
b. Gypsum Drywall System: Division 9 (0925)
4. Quality assurance:
a. Thermal Conductivity: K=.15 (ASTM-C-177-85)
b. R-Factor = 7.3 per inch aged 90 days at 73 F or 6.75 per
inch aged 90 days at 140 F (ASTM-C-177-85)
c. Density = 1.8 - 1.9 lbs/cu ft. in-place (ASTM-D-1622)
d. Permeance = .80 at 2.5 inch thickness
e. Surface Burning Characteristics: Class I at 4",
ASTM-E-84-91a.
**Flame Spread <25, Smoke density <450. **Warning:
Polyurethane foam products may present an unreasonable fire
risk unless protected by an approved thermal barrier with a
finish rating of not less than 15 minutes.
f. Independent 3rd Party Labeling: Satisfies labeling
requirements of UBC Section 2602.3, BOCA Section 2603.2 and
SBCCI Section 2603.1.2, and IBC Section 2603.2
g. Recognizable lavender color. |
5. Product handling
a. Do not allow containers to be stored in direct sunlight.
Keep drums covered. Empty container disposal by technicians
in accordance with current law.
b. Store raw materials at 55 F to 70 F.
c. Fire hazard class of raw material stored on site:
Combustible liquid,Class 3B.
d. Transportation Class 55, NOIBN, Non-Hazardous.
e. WARNING: Breathing hazard during application of
insulation materials. Do not enter without proper
respiratory protection. No smoking or open flame.
6. Job conditions
a. Examination of substrate: Technicians will examine the
substrate and conditions under which the spray insulation
work is to be performed, and notify the contractor in
writing of any unsatisfactory conditions, such as:
1. Excessive dirt or oil on substrate.
2. Excessive moisture present as dampness, dew, frost, or
water.
3. Substrate temperatures outside applicable limits.
b. Cover tools and work of other trades as required to
prevent damage from overspray.
c. Do not weld or torch near CORBONDŽ . Cover as soon as
possible with subsequent work.
II. Products
A. Materials
1. Crawlspace Perimeter Insulation: CORBONDŽ Performance
Insulation System installed to thickness shown on plans and
drawings.
2. Rigid Perimeter Wall Insulation: CORBONDŽ Performance
Insulation System installed to thickness shown on plans and
drawings.
3. Rigid Ceiling/Roof Insulation: CORBONDŽ Performance
Insulation System installed to thickness shown on plans and
drawings.
III. Execution
A. Installation
1. Installation of the CORBONDŽ Performance Insulation
System is performed by technicians familiar with the
processing of two component polyurethane foams and in
complete accord with application instructions provided by
the manufacturer. These technicians use equipment with
preset component ratio and electronically controlled heat
input to assure in-place consistency of finished product and
performance. Contact L-Squared Insulation at